CBBYL - REPLENISHER RP58SM, 12939-0035
- MSDS: CBBYL
- Manufacturer: CALCOMP
- Product Name: REPLENISHER RP58SM, 12939-0035
- National Stock Number: 6750-00N036182
Product Identification
Product ID:REPLENISHER RP58SM, 12939-0035
MSDS Date:05/21/1992
FSC:6750
NIIN:00N036182
MSDS Number: CBBYL
Responsible Party
ANAHEIM, CA 92801
US
Emergency Phone: 800-424-9300 (CHEMTREC)
Info Phone: 714-821-2730
Cage: IO122
Contractor
Telephone: 714-821-2290
Cage: 14668
Ingredients
HYDROTREATED HEAVY NAPHTHA (PETROLEUM); (ALIPHATIC
CAS: 64742-48-9
Fraction By Weight: >80%
OSHA PEL 300 PPM (MFR)
ACGIH TLV: 300 PPM (MFR)
POLY-2-ETHYLHEXYL METHACRYLATE COPOLYMER
Fraction By Weight: <10%
OSHA PEL N/K
ACGIH TLV: N/K
MAGENTA PIGMENT; QUINOACRIDINE DERIVATIVE; (PIGMENT
Fraction By Weight: <10%
OSHA PEL N/K
ACGIH TLV: N/K
VOLATILE, COMBUSTIBLE VAPORS FROM ABSORBED
RTECS: 9999999ZZ
PETRO BASED OILS. CONT LICENSED HAZ WASTE
RTECS: 9999999ZZ
DISP METH INCL INCIN/RECYCLING FOR USE AS PARTS
RTECS: 9999999ZZ
HEATING, AIR CONDITIONING & REFRIGERATING ENGINEERS
RTECS: 9999999ZZ
UNDER SOME CNDTNS OF USE/COMBINATIONS OF EQUIP,
RTECS: 9999999ZZ
VENT IS SUFFICIENT TO PVNT EXCEEDING EXPOS LIM.
RTECS: 9999999ZZ
INDUSTRIAL HYGIENIST IF A CONCERN REGARDING EXPOSURE
RTECS: 9999999ZZ
MACHINES AS REPLENISHERS MAY STAIN CLTHG.
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: SKIN: CAN CAUSE DRYING OF
SKIN/IRRIT. EYES: CONT MAY CAUSE IRRIT. INHAL: VAPS MAY CAUSE HDCH
& DIZZ. INGEST: PROD HAS LOW ORDER OF ACUTE ORAL & DERMAL TOX, BUT
IF ASPIR INTO LUNGS DURING INGEST /VOMIT, MAY CAUSE MILD TO SEV
PULM INJURY & POSS DEATH. HIGH VAP CONCS (> 1000 PPM) ARE IRRIT TO
EYES (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: & RESP TRACT, MAY CAUSE HDCH & DIZZ,
ARE ANESTH & MAY HAVE OTHER CNS EFTS. DEATH IS POSS IF EXPOSED TO
VERY HIGH CONC FOR PRLNG PERIODS. CHRONIC: LAB ANIMAL STUDIES HAVE
SHOWN THAT PRLNG & R PTD INHAL EXPOS TO LIGHT HYDROCARBON VAPS IN
SAME NAPHTHA BOILING RANGE AS PROD CAN PRDCE ADVERSE KIDNEY EFTS
(SUP DAT)
Medical Cond Aggravated by Exposure:PERSONS SENSITIVE TO HYDROCARBON
EXPOSURE MAY EXPERIENCE DISCOMFORT WHEN EXPOSED TO CONCENTRATIONS
BELOW THE ESTABLISHED SAFE EXPOSURE LIMIT. SKIN CONTACT MAY
AGGRAVATE AN EXISTING DERMATITIS.
First Aid
First Aid:EYE: FLUSH W/CLEAR WATER FOR AT LEAST 15 MIN/UNTIL IRRIT
SUBSIDES. IF IRRIT PERSISTS, CONT MD. SKIN: REMOVE CONTAM CLTHG.
WASH SKIN THORO W/SOAP & WATER. DO NOT REUSE CONTAM CLTHG UNTIL
SOLV HAVE BEEN REMOVED. INHAL: REMOVE TO FRESH AIR. CALL MD IMMED.
IF BRTHG IS IRREG/STOPPED, START RESUSCITATION IF TRAINED. ADMIN
OXYGEN IF AVAIL. INGEST: DILUTE CONTENTS OF STOM W/SEVERAL GLASSES
OF (SUP DAT)
Fire Fighting
Flash Point Method:TCC
Flash Point:>102F,>39C
Lower Limits:0.8%
Upper Limits:7.0%
Extinguishing Media:USE FOAM, DRY CHEMICAL, CARBON DIOXIDE. USE WATER
SPRAY (FOG) TO COOL FIRE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. NORMAL PROC FOR COMBUST LIQ. AVOID EXTINGUISHING W/WATER. IT
TENDS TO SPREAD HYDROCARBON SOLVENT FIRES.
Unusual Fire/Explosion Hazard:KEEP PROD AWAY FROM SOURCES OF IGNIT SUCH
AS HEAT, SPARKS, PILOT LIGHTS, STATIC ELEC, ELEC APPLIANCES & OPEN
FLAMES.
Accidental Release
Spill Release Procedures:ELIM ALL IGNIT SOURCES. RECOVER FREE PROD BY
ADDING SAND, EARTH/OTHER SUITABLE ABSORB TO SPILLED LIQ. KEEP
NON-ESSENTIAL PERS AWAY. AVOID BRTHG VAPS. VENT CONFINED SPACES.
CLEAN-UP ABSORB MATL & DISP OF PROPERLY. CONTINUE TO OBSERVE PREC
FOR (ING 4)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:"EMPTY" CONTAINERS RETAIN RESIDUE
(LIQUID AND/OR VAPOR) AND CAN BE DANGEROUS. DISPOSE OF PROPERLY.
Other Precautions:KEEP CONTAINER CLOSED WHEN NOT IN USE. DO NOT SMOKE
WHEN USING PRODUCT. MINIMIZE BREATHING OF VAPOR OR MIST. USE WITH
ADEQUATE VENTILATION. AVOID PROLONGED OR REPEATED SKIN CONTACT.
Exposure Controls
Respiratory Protection:NOT NEEDED WHEN USED AS INTENDED WITH CALCOMP
PRODUCTS. IN CONCENTRATIONS EXCEEDING THE RECOMMENDED SAFE EXPOSURE
LIMIT, SUCH AS DURING A MAJOR SPILL, USE A NIOSH/MSHA APPROVED
CHEMICAL CARTRIDGE RESP IRATOR EFFECTIVE FOR ORGANIC VAPORS.
Ventilation:NO SPEC VENT IS NEEDED WHEN USED AS INTENDED W/CALCOMP
PRODS. NORM OFFICE VENT CONFORMING TO AMERICAN SOCIETY OF (ING 7)
Protective Gloves:NITRILE OR NEOPRENE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:SHOULD NOT BE NEEDED WHEN USED AS INTENDED
IN CALCOMP PRODUCTS. WEAR A CHEMICAL RESISTANT APRON WHEN CLEANING
(ING 11)
Work Hygienic Practices:WHENEVER HANDLING CHEMICALS, ALWAYS USE GOOD
PERSONAL HYGIENE PRACTICES, SUCH AS WASHING YOUR HANDS AFTER DONE.
Supplemental Safety and Health
SPEC GRAV: 0.75-0.82 (H*2O=1). EFTS OF OVEREXP: IN MALE RATS. IT IS
HIGHLY UNLIKELY THAT KIDNEY EFTS OBSERVED IN MALE RATS HAVE
SIGNIFICANT IMPLICATIONS FOR HUMANS AT/BELOW REC VAP LIM IN
WORKPLACE. F IRST AID PROC: WATER. DO NOT INDUCE VOMIT. CALL MD
IMMED.
Chemical Properties
Boiling Pt:B.P. Text:>320F,>160C
Vapor Pres:<10 @ 25C
Vapor Density:5.0
Spec Gravity:SUP DAT
pH:NEUT
Evaporation Rate & Reference:0.3 (N-BU AC=1)
Solubility in Water:NEGLIGIBLE (0.1%)
Appearance and Odor:MAGENTA LIQUID, WITH FAINT PETROLEUM HYDROCARBON
ODOR
Percent Volatiles by Volume:80-98
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDANTS LIKE LIQUID CHLORINE, CONCENTRATED OXYGEN, AND SODIUM
HYPOCHLORITE OR CALCIUM HYPOCHLORITE.
Stability Condition to Avoid:SOURCES OF IGNITION.
Hazardous Decomposition Products:SMOKE, CARBON MONOXIDE, ALDEHYDES, &
OTHER DECOMPOSITION PRODUCTS WHICH MAY OCCUR IN THE EVENT OF
INCOMPLETE COMBUSTION.
Disposal
Waste Disposal Methods:RCRA HAZ WASTE # D001. WASTE TONERS &
REPLENISHERS ARE HAZ WASTES AS DEFINED BY 40 CFR CHAPTER 1. ASSURE
CONFORMITY W/ALL APPLIC FED, STATE & LOC DISP REGS. WASTE TONERS &
REPLENISHERS ARE COMPATIBLE FOR DISP W/MOST NON-HALOGENATED SOLV &
(ING 5)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.